There and back
The formula uses twice the length you enter, because the current returns through the negative conductor.
Calculator
Enter current, length, cross-section and system voltage. You see what is left at the end of the cable, in volts and in percent.
The result is guidance based on your input. Manufacturer instructions and local regulations always take precedence; you remain responsible for the installation.
Every conductor has resistance. At high current over a long run you lose voltage that never reaches your load but heats the cable instead. At 12V that hurts: one volt of loss is over 8 % of your system voltage, so lights dim, an inverter alarms or a charger never fills the battery.
The formula uses twice the length you enter, because the current returns through the negative conductor.
Twice as thick halves the loss. Doubling the length doubles the loss.
For charge currents and inverters 1 to 2 % is common, for lighting 3 %; the manufacturer decides.
Designing a complete electrical system? In WireElectric the voltage drop is calculated for every connection in your diagram, including the links between battery, distributor and load.
You can start drawing without an account.
Open WireElectric
Every calculator answers one question about your installation. WireElectric then runs the same calculations for every connection in your complete diagram.
Find the cross-section that suits your 12V or 24V system, based on current, length and voltage drop.
View →Find a suitable fuse for your circuit, including a check on whether the cable can carry it.
View →Work out how much battery capacity in Ah you need for your daily use and autonomy.
View →Calculate how long a battery can power a load, including the usable share and inverter losses.
View →Convert power straight to current at 12V, 24V, 48V or 230V.
View →Work out indicatively how many Wp of solar panels your daily consumption needs.
View →